Storage Tanks

Storage Tank Maintenance & Repair Services

Elevate your operations with our Storage Tank solutions.

Explore how we work
Four large industrial storage tanks outside with stairs leading up to the top of each tank

Interested? Let’s talk.

Send us an enquiry

What is Storage Tank Maintenance & Repair?

We recognise the crucial role of Storage Tanks in various industries, handling hazardous materials and substances. We adhere to stringent EEMUA 159 and API 653 standards. These internationally recognised standards provide detailed guidance on ensuring the safe and reliable design, construction, inspection, and repair of storage tanks.

Who we’ve partnered with...

Key benefits of Storage Tank Maintenance & Repair Services

Magnifying glass icon

Assurance that repairs are to code

The service ensures that repairs are completed in accordance with the applicable standard, such as EEMUA 159 or API 653.

Dark Green icon - Shield with a tick to symbolise compliance or quality

Extended service life / best practice

Having repairs completed to code helps to extend the service life of the tank and ensure that it is operating in a safe and reliable manner.

Quality checklist icon

Documentation and sign-off

The service provides clients with a documented record of the repair work and the results of the NDT inspection. This documentation is important for insurance purposes and for demonstrating compliance with regulatory requirements.

Let's talk

Send one of the team a message

Not seeing what you expected?

Try using our search

Explore what our clients say

How we'll work with you

Our comprehensive Storage Tank Remedial Work Services address a wide range of factors that contribute to Storage Tank failures.

Corrosion is a prevalent cause of tank wall weakening and increased susceptibility to failure.

Our team employs advanced NDT methods to detect corrosion and implements appropriate repair techniques to restore the tank’s integrity.

Weld defects can arise during fabrication or as a result of operational damage, creating weak points in the tank walls.

We utilise expert welding techniques and rigorous inspection procedures to eliminate weld defects and ensure structural integrity.

Dents and gouges in the tank walls compromise structural integrity and increase the risk of failure.

Our team employs precise repair methods to eliminate dents and gouges, restoring the tank’s strength and serviceability.

UKAS - ISO/IEC 17020:2012

UKAS - ISO/IEC 17020:2012 is an accreditation standard for inspection bodies. As a type A accredited inspection body, we're demonstrating our competence in carrying out inspections compliant with the Lifting Operations and Lifting Equipment Regulations (LOLER), the Provision of Workplace Equipment Regulations (PUWER), the Control of Substances Hazardous to Health regulations (COSHH), and the Pressure Systems Safety Regulations (PSSR). The Carriage of Dangerous Goods & Use of Transportable Pressure Equipment Regulations 2009 (as amended) • The Carriage of Dangerous Goods & Use of Transportable Pressure Equipment (Northern Ireland) Regulations 2010 (as amended) • The Merchant Shipping (Dangerous Goods and marine Pollutants) regulations 1997

  • British Engineering Services Limited
Find out more

Our Storage Tank Repair process adheres to stringent industry standards, such as EEMUA 159 and API 653, ensuring the safety and reliability of the repaired tank. All materials used in the repair are certified to meet the required standards for safe and reliable operation.

Plus Icon

Welding techniques

Precise welding techniques are employed to restore the tank’s integrity, ensuring structural soundness and leak-tightness.

Plus Icon

Patching and material replacement

Appropriate patching materials, such as steel plates or composite materials, are selected and applied to the damaged areas to restore the tank’s structural integrity.

Plus Icon

Rigorous NDT verification

The repaired areas are subjected to comprehensive NDT testing, including Ultrasonic Testing, Magnetic Particle Testing, Dye Penetrant Testing, and Radiographic Testing, to verify the effectiveness of the repair and confirm the Tank’s structural integrity.

Engineers inspecting a large oil tank for defects

Our comprehensive tank remedial work process

Speak to us about the process

Let’s talk. Ask us anything.

Send one of the team a message

Why choose BES Group?

An icon of people standing in a circle

35,000 satisfied customers

A strong reputation for providing exceptional service.

800+ expert
engineers

Our team of skilled engineers possesses a wealth of expertise.

A legacy of 160+ years
of experience

We’re always evolving our approach to future proof our services.

We’re qualified

Our team of technicians have completed EEMUA 159 / API 653 training, which means they’re well-equipped to ensure the ongoing compliance, safety, and efficiency of your assets.

Need more? Learn more about us

Frequently asked questions

What Inspection methods are used prior to Storage Tank Maintenance?

We employ a range of advanced NDT methods to detect hidden defects or anomalies that may not be visible to the naked eye. These methods include:

    • Ultrasonic Testing (UT): UT measures the thickness of the tank wall, providing insights into the extent of corrosion or damage.
    • Magnetic Particle Testing (MPI): MPI detects surface discontinuities in the tank’s material, such as cracks or delaminations.
    • Dye Penetrant Testing (DPI): DPI highlights cracks and defects by penetrating into the tank’s surface and revealing them under ultraviolet light.
    • Radiographic Testing (RAD): RAD uses high-energy X-rays to create detailed images of the tank’s internal structure, revealing any hidden defects or voids.

The collected NDT data is meticulously analysed to assess the severity of the damage and determine the appropriate repair approach. Our team conducts a root cause analysis to identify the underlying factors that contributed to the tank damage. This helps to prevent similar issues from reoccurring in the future.

What will be included in my Storage Tank Maintenance report?

Detailed NDT reports are generated for each NDT method used, providing clear documentation of the test results and their interpretation. This will also include:

  • Regulatory compliance documentation: All regulatory compliance documents are included in the report, demonstrating adherence to relevant safety standards.
  • Insurance purposes: The report serves as valuable evidence for insurance purposes, demonstrating the thoroughness and compliance of the repair work.
  • Maintenance records: The report is integrated into the tank’s maintenance records, providing a complete history of the tank’s condition and repairs.

What additional Testing methods are used after Storage Tank Maintenance or Repairs ?

  • Pressure testing: The Tank will undergo Pressure Testing to ensure its ability to withstand the operating pressures and avoid sudden failures.
  • Hydrostatic testing: For Water Tanks, hydrostatic testing is conducted to ensure the Tank can withstand the maximum operating pressure while maintaining its structural
Need more help? Let’s talk.

Sectors we service

Dive into the diverse landscapes where BES Group sparks innovation and drives impact.

Explore all our sectors

Let’s talk. Ask us anything.

Send one of the team a message

Other similar services...

Looking for something else? Explore similar services...